How much does a 22 kW standby generator cost in Raleigh, NC?
| Typical totalinstalled, 22 kw | $11,821 |
|---|---|
| Range you should see in bidsthree bids on the same scope normally land inside this | $8,638 – $15,913 |
| Labor portion45% of the job — this is the part that moves by city | $5,319 |
| Material portion55% — bought at national prices | $6,501 |
| Electricians pay near Raleighabout $27/hr · Raleigh-Cary, NC metro | $57,080/yr |
| U.S. mean for the same tradeSOC 47-2111 | $71,490/yr |
| Versus the national pricetrade pay here runs −20.2% against the U.S. mean | −$1,179 |
Notes
- Where the number comes from. The national price for a 22 kW standby generator installed is $13,000 installed — standby generator pricing published for 2026, unit plus installation. Labor is about 45% of that. Electricians near Raleigh, NC average $57,080 a year against a U.S. mean of $71,490 — a factor of 0.798 — so the labor half is scaled by that and the material half is not. Source: BLS OEWS May 2025 for the Raleigh-Cary, NC metro area, SOC 47-2111.
- Why the city matters, not just the state. Trade pay moves inside a state as much as it does between states. Crews do not commute across a state to bid a job, and materials ship at national prices either way — so a metro wage is the honest input here and a state average quietly rounds four different cities into one number.
- What is in the price: the generator, a concrete or composite pad, the transfer switch, electrical connection, gas piping from an existing supply, permit and commissioning.
- What is not: a propane tank and its burial, a gas meter upsize where the utility requires one, trenching over long distances, and the annual service contract. These are the lines that turn a $11,821 quote into a $14,776 invoice, so ask about each one before signing.
- Use this as a bid check, not a quote. It prices an average job in average condition. Difficult access, the state of what is being replaced, the season, and a crew booked out three months all move the real number, and none of them are in a national average for the job.
a 22 kW standby generator installed in Raleigh, NC
$11,821 is the typical number, and three bids on the same scope normally land between $8,638 and $15,913.
That is $1,179 less than the same job priced at the national average.
Why the city changes the number
About 45% of this job is labor — $5,319 of the $11,821 above. Labor is the only part that moves locally; a bundle of material costs what it costs wherever it is nailed down.
Electricians near Raleigh average $57,080 a year, against a U.S. mean of $71,490. That is a factor of 0.798, so the labor half is scaled by it and the material half is not.
Source: BLS OEWS May 2025 for the Raleigh-Cary, NC metro area, SOC 47-2111.
What the quote should include
The lines that turn a quote into an invoice
Ask about each of them before you sign. On a job this size they are the difference between $11,821 and something a quarter higher.
Use it as a bid check, not a quote
This prices an average job in average condition. Access, the state of what is being replaced, the season, and a crew booked out three months all move the real number, and none of them are in a national average.
If a bid lands outside $8,638 – $15,913, that is not automatically wrong — but it is the question worth asking out loud.
Nearby sizes
- How much does a 22 kW standby generator cost in Omaha, NE?
- How much does a 22 kW standby generator cost in Kansas City, MO?
- How much does a 22 kW standby generator cost in Miami, FL?
- How much does a 22 kW standby generator cost in Long Beach, CA?
- How much does a 14 kW standby generator cost in Raleigh, NC?
Read more
- Choosing an Installer — The Questions That Separate ThemEvery brand makes an adequate generator. Not every dealer will be reachable on the third day of an outage.
- Where the Generator Goes — Clearances, Noise and Carbon MonoxideCarbon monoxide from portable generators kills people every storm season, and the distances involved are larger than intuition suggests.
- Noise — The Objection That Arrives After the InstallationThe generator is quiet enough during the storm that caused the outage and much less so at ten on a Tuesday morning.
- What a Standby Generator Installation Is Made OfTwo quotes on the same house differ mostly on how far the generator is from the meter and the panel.